An Unexpected Complication During Endovascular Aortic Repair: Covered-Stent Migration Into the Aortic Arch, and an Endovascular Solution: Case Report
Levent Çeti̇n, Murat Canyi̇ği̇t, Aslıhan Küçüker, Mete Hidiroglu, Ayşegül Kunt, Erol Şener
DOI: 10.9739/uvcd.2014-39702 · Page: 085-089 · 34 Views · 0 Downloads · 0 Citations
Abstract
Endovascular aortic stent-grafting has become a promising therapeutic alternative to
open aortic surgery for all pathologies affecting the descending thoracic and abdominal aorta. A variety
of unexpected complications related to these procedures may occur requiring prompt solutions.
In those circumstances, knowledge of endovascular techniques and solutions are important. Herein,
we present a worrying complication implying complete migration of the balloon-expandable covered
stent of subclavian artery into the aortic lumen, and the endovascular solution of the problem. We
believe that reporting such complications is important and informative, as it serves to pick up little
but important tricks for our colleagues who perform similar endovascular interventions. We think
that, we may learn from our complications, and share them with our colleagues in this way.
Keywords : Endovascular interventions; stent migration; left subclavian artery coverage; complication